id: CVE-2025-59703
title: >-
  Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or
  13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate
  Attacker to access the internal components of the appliance, without leaving
  tamp…
summary: >-
  Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or
  13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate
  Attacker to access the internal components of the appliance, without leaving
  tamp…
severity: critical
cvss: 9.1
cvssVector: 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N'
cwe:
  - CWE-284
vendor: entrust
product: nshield_5c_firmware
affected:
  - nshield_5c_firmware < 13.6.12
  - 'nshield_5c_firmware >= 13.7, < 13.9.0'
  - nshield_hsmi_firmware < 13.6.12
  - 'nshield_hsmi_firmware >= 13.7, < 13.9.0'
  - nshield_connect_xc_base_firmware < 13.6.12
  - 'nshield_connect_xc_base_firmware >= 13.7, < 13.9.0'
  - nshield_connect_xc_mid_firmware < 13.6.12
  - 'nshield_connect_xc_mid_firmware >= 13.7, < 13.9.0'
  - nshield_connect_xc_high_firmware < 13.6.12
  - 'nshield_connect_xc_high_firmware >= 13.7, < 13.9.0'
patched:
  - nshield_5c_firmware 13.9.0
  - nshield_hsmi_firmware 13.9.0
  - nshield_connect_xc_base_firmware 13.9.0
  - nshield_connect_xc_mid_firmware 13.9.0
  - nshield_connect_xc_high_firmware 13.9.0
published: '2025-12-02'
updated: '2026-08-26'
source: NVD
sourceUrl: 'https://nvd.nist.gov/vuln/detail/CVE-2025-59703'
references:
  - url: 'https://github.com/advisories/GHSA-h78c-68qv-3qg9'
    label: cve@mitre.org
  - url: >-
      https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj
    label: cve@mitre.org
  - url: >-
      https://www.entrust.com/knowledgebase/hardware/understanding-nshield-security-advisory-september-2025
    label: cve@mitre.org
  - url: 'https://www.entrust.com/use-case/why-use-an-hsm'
    label: cve@mitre.org
tags:
  - nvd
epss: 0.00462
epssPercentile: 0.37499
ingestedAt: '2026-08-26T16:46:30.358Z'
---

## Overview

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.

## Affected

- `nshield_5c_firmware < 13.6.12`
- `nshield_5c_firmware >= 13.7, < 13.9.0`
- `nshield_hsmi_firmware < 13.6.12`
- `nshield_hsmi_firmware >= 13.7, < 13.9.0`
- `nshield_connect_xc_base_firmware < 13.6.12`
- `nshield_connect_xc_base_firmware >= 13.7, < 13.9.0`
- `nshield_connect_xc_mid_firmware < 13.6.12`
- `nshield_connect_xc_mid_firmware >= 13.7, < 13.9.0`
- `nshield_connect_xc_high_firmware < 13.6.12`
- `nshield_connect_xc_high_firmware >= 13.7, < 13.9.0`

## Remediation

Upgrade past the affected range:

- `nshield_5c_firmware 13.9.0`
- `nshield_hsmi_firmware 13.9.0`
- `nshield_connect_xc_base_firmware 13.9.0`
- `nshield_connect_xc_mid_firmware 13.9.0`
- `nshield_connect_xc_high_firmware 13.9.0`