{"id":"CVE-2026-16933","title":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in th…","summary":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in th…","severity":"high","cvss":8.2,"cvssVector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","cwe":["CWE-190"],"published":"2026-08-19","updated":"2026-08-22","source":"NVD","sourceUrl":"https://nvd.nist.gov/vuln/detail/CVE-2026-16933","references":[{"url":"https://www.ibm.com/support/pages/node/7283216","label":"psirt@us.ibm.com"}],"tags":["nvd"],"epss":0.00123,"epssPercentile":0.02405,"ingestedAt":"2026-08-23T03:41:35.248Z","slug":"CVE-2026-16933","body":"## Overview\n\nIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.\n\n## Remediation\n\nRefer to the linked advisories for vendor-supplied fixes and affected version ranges.","depth":"twilight","depthScore":45,"depthScoreParts":{"impact":45.1,"likelihood":0,"exploitation":0,"ransomware":0},"changes":[]}