{"id":"CVE-2025-61940","title":"NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database","summary":"NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the unde…","severity":"high","cvss":8.3,"cvssVector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L","cwe":["CWE-603"],"vendor":"mirion","product":"biodose/nmis","affected":["biodose/nmis < 23.0"],"patched":["biodose/nmis 23.0"],"published":"2025-12-02","updated":"2026-09-25","sourceUpdated":"2026-09-25T23:10:00.463","source":"NVD","sourceUrl":"https://nvd.nist.gov/vuln/detail/CVE-2025-61940","references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01","label":"ics-cert@hq.dhs.gov"}],"tags":["nvd"],"epss":0.00323,"epssPercentile":0.22738,"ingestedAt":"2026-09-25T23:21:16.866Z","slug":"CVE-2025-61940","body":"## Overview\n\nNMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection.\n\n## Affected\n\n- `biodose/nmis < 23.0`\n\n## Remediation\n\nUpgrade past the affected range:\n\n- `biodose/nmis 23.0`","depth":"twilight","depthScore":46,"depthScoreParts":{"impact":45.7,"likelihood":0.1,"exploitation":0,"ransomware":0},"changes":[]}